Insulation Class | F |
Cooling Type | Liquid cooled |
Compressed air supply, P1min- P1max | 5.0-10 bar (72-145 psi) |
Duty Factor, x | 10% |
Maximum short circuit input current, ILCC | 109A |
Permanent power (100% duty factor), SP | 128 kVA |
Permanent input current, ILP | 161A |
Maximum short circuit output current, 12CC | 16.0 kA |
Dimensions | 45" x 26" x 37" |
Max. Voltage | 3 x 460V -5% +10%, 50 Hz- 60Hz |
Power Supply Fuse | 30A slow blow or circuit breaker Type K |
Protection Type | IP21 |
Permanent output current (100% duty factor), I2P | 15.8 kA |
No-load voltage, U2D | 14.5 V |
Cooling power | 1000W |
Tank capacity | 20 l (5.3 gal) |
Rated cooling liquid flow, Q | 3 l/min (0.79 gal/min) |
Cooling liquid pressure drop | 1.79 bar (26.0 psi) |
Electrode force, FMIN - FMAX | 350-640 daN (787-1439 ibf) |
Weight | 273.5 lbs. |
Cable Length | 6 m (19.7 ft) |